Home > Products > EPS Pre-expander
EPS Batch Pre-expander (Standard type)

Main Feature
1.“Yoshitake” Pressure Reduction Valve from Japan is used for steam control
2.Equipped with weighting sensor to increase density accuracy
3.Insulation layer to reduce energy consumption
4.Second expansion is available for lower density
5.Fluid bed is equipped with heater to shorten aging time
6.Five safety features to insure safe operation
7.Safety fence on top

 

Item

Unit

SPJY1200(LH)

SPJY1400(LH)

SPJY1600-1/2(LH)

Chamber diameter

mm

1200

1400

1600

Chamber height

mm

2000

2000

2500

Volume

m3

2

2.7

5

Steam Pressure

Mpa

0.6

0.6

0.6

Air Pressure

Mpa

0.6-0.8

0.6-0.8

0.6-0.8

Density range

g/l

6-25

6-25

6-25

Tolerance

g/l

±3%

±4%

±4%

Capacity

Kg/hr

200-800

400-1000

600-1800

Power

Kw

17.5

24

31

Voltage

V/Hz

380/50

380/50

380/50

Contour size

mm

5600*3100*4200

7600*3500*5000

7600*3700*6000

Weight

Kg

2300

3500

5500